Brocade Fabric OS v7.2.1 Release Notes v1.0

Closed with Code Change in Fabric OS v7.2.1
Fabric OS v7.2.1 Release Notes v1.0 Page 44 of 49
Defect ID:
DEFECT000467589
Technical Severity:
Medium
Summary:
snmpconfig does not show community 1 during configuration on v7.1.1
Symptom:
User cannot configure "community 1" with snmpconfig --set command
Risk of Fix:
Medium
Probability:
Medium
Feature:
FOS Software
Function:
SNMP
Reported In Release:
FOS7.1.1
Service Request ID:
1194854
Defect ID:
DEFECT000467681
Technical Severity:
High
Summary:
Blade server shows incorrect firmware version in IOM module after a switch hotplug
Symptom:
Blade server still displays older Firmware Version in IOM module after upgrade and shows none after
switch hotplug
Risk of Fix:
Low
Probability:
High
Feature:
Embedded Platform Services
Function:
Other
Reported In Release:
FOS7.2.0
Service Request ID:
1001
Defect ID:
DEFECT000467760
Technical Severity:
Medium
Summary:
Disabled port is not getting enabled after binding a port address.
Symptom:
Port is disabled after binding a port address.
Workaround:
Nonw
Risk of Fix:
High
Probability:
Low
Feature:
WebMgmt
Function:
Ports Admin
Reported In Release:
FOS7.2.0
Defect ID:
DEFECT000468007
Technical Severity:
High
Summary:
Host discovery issues via Ex ports on ICL in multi chassis configuration
Symptom:
Host may not see all target LUNs in a topology using multi-chassis EX ports on ICL configuration
Workaround:
Portdisable enable switch ports for affected devices.
Risk of Fix:
Low
Probability:
Medium
Feature:
FC Services
Function:
Name Server
Reported In Release:
FOS7.2.0
Defect ID:
DEFECT000468152
Technical Severity:
High
Summary:
after zone change nszonemember missing members and ports show HARD_PORT dhp bit set: 1
Symptom:
A zoning change (removal) was made from the core switch at which time the name server stopped
responding, causing outages on the hosts.
Workaround:
Allow 5 minutes delay between cfgsave and cfgenable command
Risk of Fix:
Low
Probability:
Low
Feature:
FOS Software
Function:
Fabric Services
Reported In Release:
FOS7.0.2
Service Request ID:
1202661,1249899,7610
Defect ID:
DEFECT000468188
Technical Severity:
High
Summary:
Observed MDD kept crashing when a DS was set persistently disabled
Symptom:
User may see MDD hit rolling crashing when the switch is configure VF mode and the DS switch is
set disable persistently with MAPS enabled.
Risk of Fix:
High
Probability:
Low
Feature:
Advanced Monitoring Services
Function:
Other
Reported In Release:
FOS7.2.0