HP Store Once 2700, 4500 and 4700 Maintenance and Service Guide

2. To drill down to the hardware component causing the problem run the StoreOnce CLI command:
hardware show status <Dev-id>
# hardware show status
Name Dev-id Status
-------------------- ------------------------------------ --------
HPCZ225101H9 34303936-3738-5A43-3232-353130314839 DEGRADED
p1224 Storage System 02358fe6-0000-1000-b012-53344230334b DEGRADED
p1224 Storage System 010e9a23-0000-1000-b01c-533442303034 OK
# hardware show status 02358fe6-0000-1000-b012-53344230334b
Name Dev-id Status
-------------------- ------------------------------------ --------
p1224 Storage System 02358fe6-0000-1000-b012-53344230334b DEGRADED
- 50014380254FAD32 DEGRADED
Drawer 1 500143802050F740 DEGRADED
Pools pools-1 DEGRADED
Controller 1 50014380254FAD30 OK
# hardware show status 50014380254FAD32
Name Dev-id Status
----------------------- ---------------------- --------
- 50014380254FAD32 DEGRADED
Disk 5000C50055C1BB0B 5000C50055C1BB0B OK
- Drive_Missing_b1000103 FAILED
3. When you reach the faulty component, use the following command to display details and
look at the diagnostic message for more information.;
hardware show status <Dev-id> details
For example:
# hardware show status 50014380254FAD32 details
Name
----------------------------------------------
-
Dev-id = 50014380254FAD32
Status = DEGRADED
message = -
type = driveEnclosure
model = ServBP 4
serialNumber = -
firmwareVersion = -
location = -
Disk 5000C50055C1BB0B
Dev-id = 5000C50055C1BB0B
Status = OK
message = -
type = drive
model = MM1000FBFVR
serialNumber = 9XG3601K00009316ZLN0
firmwareVersion = HPD8
location = Port: 1I Box: 2 Bay: 1
volumeName = LUN 1
capacity = 1.00 TB
-
Dev-id = Drive_Missing_b1000103
Status = FAILED
Using the StoreOnce CLI 19