3 Identifying problems
If you have configured recipients for SNMP traps or email alerts, they will be notified of any
problems with hardware components. You can also use the StoreOnce GUI and StoreOnce CLI
as described below.
Example alerts
The following alerts were triggered by a problem with a failed disk in an HP StoreOnce 4900
Backup system.
The following event occurred: hardwarecomponent.failure
Severity: ALERT
Date: Wed Jan 21 14:19:21 UTC 2013
Appliance: HPCZ225101H9
System URL(s): http://<IP_address1>, http://<IP_address2>
component:drive, status:FAILED, location:drive S/N:5C7229P34B in bay 11 in Drawer 2 of driveEnclosure
S/N:CZ7229P340:, Message: The drive is not ready and will not spin up., Diagnostic message: Reseat the drive.
If reseating the drive does not resolve the issue, replace the drive., uuid:Drive_Missing_b1000085,
eventId:00030002, level:ALERT, category:STORAGE_CLUSTER, overallStatus:DEGRADED, name:
vs_02358fe6-0000-1000-b012-53344230334b