HP Store Once 4900 Backup Maintenance and Service Guide

Table Of Contents
# hardware show status 051662fb-0000-1000-b027-53344a303131
Name Dev-id Status
-------------------- ------------------------------------ --------
p1228 Storage System 051662fb-0000-1000-b027-53344a303131 DEGRADED
Enclosure CZ3320E200 DEGRADED
Pools pools-1 OK
Controller 1 5001438025A26200 OK
# hardware show status CZ3320E200
Name Dev-id Status
----------------------- ---------------------- --------
- 50014380254FAD32 DEGRADED
Disk 5000C50055C1BB0B 5000C50055C1BB0B OK
- Drive_Missing_b1000103 FAILED
3. When you reach the faulty component, use the following command to display details and
look at the diagnostic message for more information.;
hardware show status <Dev-id> details
4. After identifying the issue that needs to be corrected, follow the instructions in the relevant
chapter of this guide.
5. Be sure to check that all problems have been resolved. Re-run the StoreOnce CLI command:
hardware show problems
The output returned should now be blank.
12 Identifying problems