HP Store Once 4900 Backup Maintenance and Service Guide
Table Of Contents
- Backup system service and maintenance guide for HP StoreOnce 4900 Backup
- Contents
- 1 Spares part numbers for field replacement
- 2 General information
- 3 Identifying problems
- 4 Replacing the system motherboard
- 5 The HP p1228 RAID controller
- 6 RAID cache module and SuperCapacitor failures
- 7 Disk enclosures
- 8 Disk replacement
- 9 The QR ISO image
- 10 Support and other resources
- 11 Documentation feedback
warning events will be generated and the GUI Event Log will show errors being reported and
cleared.
9. Run the StoreOnce CLI command, hardware show firmware node, to check that the
firmware on the new RAID card is correct; it will be listed under the node (server) details. Run
the StoreOnce CLI command, hardware update firmware node, with appropriate
parameters to update it, if necessary. See the HP StoreOnce Backup CLI Reference Guide for
more details.
NOTE: You may need a cold reboot to successfully install the new firmware revision.
Replacing the HP p1228 controller 19