System URL(s): http://_IP_Address1>, http://<IP_Address2>
component:superCapacitor, status:MISSING, location:superCapacitor in storageController S/N:PCUUVX58S4B004 in
PCI Slot 4 in server HPCZ225101H9, Message: The supercap is missing or has failed., Diagnostic message: Check
the connections to the supercap. If the supercap is fully connected, replace the supercap.,
uuid:50014380254FAA50_BAT_1, eventId:001C0004, level:ALERT, category:SERVER, overallStatus:DEGRADED, name:
ch_34303936-3738-5A43-3232-353130314839 , engine name: hpcz225101h9
Using the StoreOnce CLI
1. Run the StoreOnce CLI command:
hardware show problems
This will display warnings for all hardware components and, in our example, assist in identifying
the RAID controller and component that is causing a problem.
2. To drill down to the hardware component causing the problem run the StoreOnce CLI command:
hardware show status <Dev-id>
# hardware show status
Name Dev-id Status
-------------------- ------------------------------------ --------
HPCZ230805V9 33363437-3535-5A43-3233-303830355639 OK
p1228 Storage System 051662fb-0000-1000-b027-53344a303131 DEGRADED
p1228 Storage System 02abd2f6-0000-1000-b044-53344a30314d OK
# hardware show status 051662fb-0000-1000-b027-53344a303131
Name Dev-id Status
-------------------- ------------------------------------ --------
p1228 Storage System 051662fb-0000-1000-b027-53344a303131 DEGRADED
Enclosure CZ3320E200 DEGRADED
Pools pools-1 OK
Controller 1 5001438025A26200 DEGRADED
# hardware show status 5001438025A26200
Name Dev-id Status
-------------------- ------------------------------------ --------
Controller 1 5001438025A26200 DEGRADED
Cache Module 1 5001438025A26200_IOC_1 OK
Cache Battery 1 5001438025A26200_BAT_1 MISSING
# hardware show status 5001438025A26200_BAT_1
Name Dev-id Status
--------------- ---------------------- -------
Cache Battery 1 5001438025A26200_BAT_1 MISSING
3. When you reach the faulty component, use the following command to display details and
look at the diagnostic message for more information.
hardware show status <Dev-id> details
Name
----------------------------------------------------------------------
Cache Battery 1
Dev-id = 5001438025A26200_BAT_1
Status = MISSING
message = The supercap is missing or has failed
type = superCapacitor
estimatedChargeRemaining = 100%
chargeStatus = FULLY CHARGED
Identifying the cache module or SuperCapacitor failure 21