9.5 HP P4800 G2 SAN Solution for Bladesystem Maintenance Guide (AX696-96151, September 2011)

Table 2 Minimum requirements, overview category
Minimum requirementItem
CPU on the server blade: Intel Xeon Processor @ 2.40
Ghz
CPU
37 hard drives, which include the following:Type and number of drives
Slot 2: 35 drives on the HP Smart Array P700m
controller
Slot 0: 2 drives on the HP Smart Array P410i
controller
24 GBMemory
For the HP P4460sb G2 server blade, the Network
Controller is Emulex OneConnect 10Gb NIC:
v2.102.453.0 or later.
NIC
The HP P4000sb server blade has a Broadcom Network
Controller with no minimum requirement.
9. From the Categories list, select Storage.
10. Verify that the specified item meets the minimum requirements listed in Table 3 (page 16).
Table 3 Minimum requirements, storage category
Minimum requirementItem
Array Controller in Slot 0: HP Smart Array P410i
controller
Model: HP P410i
Firmware: 3.52 or later
Installed Memory: 0 MB
BIOS boot device order: 1
Array Controller in Slot 2: HP Smart Array P700m
controller
Model: HP P700m
Firmware: 7.22 or later
Installed Memory: 512 MB
Battery1: OK
BIOS boot device order: 2
Run server diagnostics
1. On the HP Insight Diagnostics Test tab, select Quick Test and specify the number of loops.
2. Click Begin Testing.
The Survey Tab displays the data from the tests.
Wait for the tests to finish, which may take several minutes.
3. When the tests have completed, select the Log tab and check the failure log to see if the Quick
Test reports any failures.
4. If the Quick Test reports any errors, fix all errors before continuing.
If you need more information about an error, run a Complete Test on any component that
reported a failure.
If you want to run only specific tests, use the Custom Test option.
For assistance with the Complete or Custom Test options, see the HP SmartStart CD x64 or
contact HP technical support.
5. Click Exit Diagnostics.
6. Disconnect the HP SmartStart CD x64 from Virtual Media and reboot.
16 Maintaining the HP P4800 G2 solution