9.5.01 HP P4000 SAN Solution User Guide (AX696-96168, February 2012)

11. Select the option Only notify me of patches available for my current version of software and
click OK.
12. Log in to the management group targeted for the upgrade and click Continue next to the
Upgrades Available (Patches).
Upgrading storage systems in a management group or available storage systems
The system upgrades one storage system at a time in management group, making every effort to
keep volumes available. The process includes all patches and upgrades.
When upgrading storage systems in the Available Systems list, all storage systems in the list are
upgraded.
Before upgrading the storage systems in a management group or available storage systems, verify
the following:
For all storage systems:
You are using Version 9.0 or later of the CMC.
All storage systems are in a good state, with no critical events.
If you are using the HP DSM for MPIO or the CLI, upgrade them first.
If you are using VSS, be prepared to upgrade it during the SAN/iQ upgrade process.
For storage systems in a management group:
You are logged in to the management groups you want to upgrade.
At least two storage systems are running managers, so you will not lose quorum.
If you want to maintain availability to volumes during the upgrade, your management
group must be configured with Network RAID-10 (2–Way Mirror) or higher.
All virtual managers in the management group are stopped.
NOTE: During the upgrade procedure, you may receive a warning that the CPU Utilization value
exceeds 90, for example: CPU Utilization = 97.8843. Value exceeds 90. This is an
expected occurrence during an upgrade. No action is needed.
To upgrade storage systems:
1. When you see an upgrade for a management group or for available systems, click Install
next to the item you want to upgrade.
2. If the Package Selection window opens, select the upgrade or patch you want to install, and
click OK.
The Package Selection window opens if you have your Upgrade Select Mode set to Advanced.
See “Setting upgrade preferences” (page 25).
The Install Action Required window opens, with a list of software that must be upgraded before
continuing with the SAN/iQ upgrade. The current versions were downloaded to your download
directory.
3. If you are using the listed software, verify that the current versions are installed, or install the
current versions
4. After verifying or installing the listed upgrades, select the check box at the bottom of the
window, and click Continue.
To stop the SAN/iQ upgrade process while you verify or install the listed software, click
Cancel.
The Upgrade Progress window opens, showing the upgrade progress for each storage system,
then the Upgrade Summary window opens. To see information about the upgrades, click
Installation Succeeded. To save the upgrade information to a file, click Export Information.
28 Working with storage systems