Read This First: User Guide Update, First Edition - HP Integrity and HP 9000 Superdome Servers
A5201-SDRTF
November 2008
HP Integrity and HP 9000 Superdome Servers
Read This First
Description
This Read This First document is for User Guide HP Integrity Superdome HP 9000 Superdome 6
th
ed. part
number A5201-96044.
Shutting Down HP-UX
On page 205, insert the following “Notes” after the sentence: “For details refer to the shutdown
(1M) manpage.” This page is located in Appendix A, Operating System Boot and Shutdown:
NOTE: On Superdome SX1000 PA, Shutdown –R –H does not stop at BIB if the MP has been hot
swapped since the last reboot.
NOTE: On HP Integrity servers you should reset an nPartition only after all self tests and
partition rendezvous have completed. For example, when the nPartition is inactive (all cells are
at BIB) or is at EFI.
MP Command: RR
On page 279, insert the following “Note” before the figure: Example F-21 RR Command. This page is
located in Appendix E, Management Processor Commands:
NOTE: On HP Integrity servers you should reset an nPartition only after all self tests and
partition rendezvous have completed. For example, when the nPartition is inactive (all cells are
at BIB) or is at EFI.