Superdome Servers - I/O Expansion Cabinet Guide, Fifth Edition

Chapter 7
Testing the IOX
Checking I/O Expansion Cabinet Status
173
Listing Power and Fan Status for I/O Expansion Cabinets
You can get power and fan status information for I/O Expansion cabinets using the following methods:
“GSP” on page 173
This procedure (GSP Command menu, DU command or PS command, B option) checks power and fan
status from the Guardian Service Processor (GSP) command menu.
“HP-UX Commands” on page 174
This procedure (parstatus -B or parstatus -V -b#) lists the status of power supplies and fans from HP-UX.
I/O Expansion cabinets are numbered 8 and 9.
GSP
This procedure (GSP Command menu, DU command or PS command, B option) checks power and fan
status from the Guardian Service Processor (GSP) command menu.
Step 1. Log in to the complex’s GSP and access its command menu.
From the GSP main menu, enter CM to access the command menu.
Step 2. For brief status, issue the DU command.
For detailed status, issue the PS command, select B for cabinet info, and specify the cabinet number
whose status you want to check.