Superdome Servers - I/O Expansion Cabinet Guide, Fifth Edition
Chapter 7
Testing the IOX
Checking I/O Expansion Cabinet Status
175
The following example shows power and fan details for cabinet number 8, an I/O Expansion
cabinet.
# parstatus -V -b8
[Cabinet]
Cabinet I/O Bulk Power Backplane
Blowers Fans Supplies Power Boards
OK/ OK/ OK/ OK/
Cab Failed/ Failed/ Failed/ Failed/
Num Cabinet Type N Status N Status N Status N Status GSP
=== ============ ========= ========= ========== ============ ======
8 SD64000 2/ 0/ N+ 4/ 0/ N+ 2/ 0/ N+ ?/ ?/ N- none
Cabinet Blowers
===============
Fan 0 ok
Fan 1 ok
I/O Fans
==============
Fan 0 ok
Fan 1 ok
Fan 2 ok
Fan 3 ok
Bulk Power Supplies(BPS)
========================
Power Supply 0 ok
Power Supply 1 ok
Notes: N+ = There are one or more spare items (fans/power supplies).
N = The number of items meets but does not exceed the need.
N- = There are insufficient items to meet the need.