Superdome Servers - I/O Expansion Cabinet Guide, Fifth Edition
Chapter 3
Installing the IOX
Connecting the IOX to the Superdome
69
Step 2. Remove the rear door of the Superdome server.
Step 3. Cut the green tie wraps and remove the green VELCRO ties holding the REO cables during
shipment.
NOTE The IOX may have one, two, or three ICEs. There are two REO cables per ICE.
Therefore, you may have to perform these steps on as many as three REO cable
pairs.
Step 4. Remove the appropriate R-PEC from the cable exit panel by loosening the two T15 Torx screws.
The REO cable pairs from the ICE mounted lowest should mount and run through the bottom
R-PEC in the cable exit panel. Likewise, the REO cables from the next higher ICE pass through the
next higher R-PEC, and so on.
In Figure 3-32, the IOX is not in place for illustrative purposes.
Figure 3-32Removing R-PEC