Superdome Servers - I/O Expansion Cabinet Guide, Fifth Edition

Chapter 3
Installing the IOX
Connecting the IOX to the Superdome
75
Step 11. Repeat Step 4. through Step 10. for each REO cable pair.
Figure 3-38Typical REO Cable Locations
Connecting the GSP Bus Cables
The GSP bus cables are very similar to the REO cables, in that they have two sections where the shield is
exposed. They are routed they same way as the REO cables and are secured to the Superdome cable exit
panel with a U-PEC (as opposed the R-PEC used for the REO cables). Each shield section is protected with
plastic covers. You remove these covers as described in the REO cable section, “Connecting the REO Cables”
on page 67.
There is only one GSP bus cable per IOX, which runs from the XUC in the IOX to the backplane of the
Superdome server.
Procedure
Step 1. Locate the GSP bus cable and remove the green tie wraps and/or green VELCRO cable ties.
Figure 3-39Identifying the GSP Bus Cable