Superdome Servers - I/O Expansion Cabinet Guide, Fifth Edition
Chapter 3
Installing the IOX
Connecting the IOX to the Superdome
77
NOTE Remove the blue shield protector when the destination server is next to the IOX.
Remove the green shield protector when the destination server is not next to it, as
with a Superdome 64 Way server.
IMPORTANT Remove the protective plastic only on the appropriate shield section. Leaving the
other shield section exposed can cause inadvertent shorting.
Figure 3-42GSP Bus Cable Shield Protector
Step 5. Separate the U-PEC into halves by removing the two T15 Torx screws.
The U-PEC has two cable holes that are filled with a blank in each hole. There is normally only one
hole used, because there is only one GSP bus cable. Therefore the blank must remain in the other
hole.Loosen the screw in the blanks to facilitate its removal.