Optical Drive and Library SCSI-2 Command Reference
SCSI-2 Drive Command Set
Erase (Group 1) Command (2CH)
Chapter 2 2-89
SCSI-2 Drive Commands
ERA   An Erase All bit of 1 indicates that all remaining blocks 
are erased, starting from the logical block address to the 
end of the disk. The transfer length must be set to 0.
  An ERA bit of 0 indicates that all blocks are erased, 
starting from the logical block address to the end of the 
specified transfer length.
Rel Adr   A relative address bit of one indicates that logical block 
address specified is a two’s complement offset from the 
last logical block address accessed.
   A value of 0 indicates that the logical block address is an 
absolute address.
Transfer 
Length   The Transfer Length field specifies the number of 
contiguous logical blocks of data to be erased. A value of 
0 indicates that no blocks will be erased and is not 
considered an error.
PBA   A Physical Block Address bit of 1 indicates that physical 
block addressing is used.
   A PBA bit of 0 indicates that logical block addressing is 
used.
NOTE If this command is executed for write-once disks, the drive returns a 
CHECK CONDITION status with the Sense Key/Additional Sense Code 
set to Illegal Request/Invalid Command Operation Code.
NOTE When this command is executed with 14X 512 or 1024 byte/sector media, 
the drive will return a CHECK CONDITION status. The sense key/
additional sense code will be set to ILLEGAL REQUEST/INVALID 
COMMAND.