Optical Drive and Library SCSI-2 Command Reference
Jukebox SCSI-2 Command Set
Read Element Status Command (B8H)
Chapter 3 3-75
Jukebox SCSI-2 CommandsJukebox SCSI-2 Commands
Element Descriptor
Length  The number of bytes in each Element Descriptor Block.
Byte Count of
Descriptor Data
Available   Element Descriptor Length for X Number of Elements 
of the type shown in byte 0.
Element 
Address    The address of the element being reported by this 
descriptor block.
Access   When set to 1, access to the element by the Medium 
Transport Element is allowed.
Except   When set to 1, the element is in an abnormal state. 
Information about the abnormal state is available in the 
Additional Sense Code and Additional Sense Code 
Qualifier bytes. (See Table B-2 on page B-4)
Full   When set to 1, the element contains a cartridge.
Not Bus   When set to 1, the SCSI Bus Address and the Logical 
Unit value fields are not on the SCSI Bus used to select 
the library.
20-23
a
Reserved (0)
24-33
a
Drive Serial Number (ASCII)
a. These fields are applicable for the 300mx, 600mx, 700mx, 1200mx and 2200mx 
models only.
Table 3-75 Read Element Status Data Transfer Element Descriptor Block 
Byte 7 6 5 4 3 2 1 0