Optical Drive and Library SCSI-2 Command Reference
Autochanger Error Codes
Jukebox Micro-Move Error Codes
Appendix BB-46
11
Mechanism Exercise 
Test
Performs a combination of moves with a pass/fail 
result. This exerciser is actually a sequence of 
other exerciser tests — 12, 13, 14, 15, 16, and 17. 
This exerciser returns an error code #57H 
Invalid Configuration if there are no cartridges 
loaded into the unit, or if any drive is full. 
Requires one loaded cartridge, drives and 
mailslot empty.
12
Carriage Move Test Performs a combination of carriage moves with a 
pass/fail result. It moves the carriage assembly 
to the maximum distance away from the sensor 
on both sides. No cartridges are required.
13
Translate Test (Not 
valid for the Model 
10LC)
Performs a combination of moves with a pass/fail 
result. It performs several translations from 
various starting positions. No cartridges are 
required.
14
Flip Test Performs a combination of moves with a pass/fail 
result. It performs several flips at various 
locations. No cartridges are required.
15
Storage Slot Test Performs a combination of moves with a pass/fail 
result. It moves a cartridge from a randomly- 
chosen full slot to a randomly-chosen empty slot, 
with a random flip. It then moves the cartridge 
back to its original storage slot with its original 
orientation. This exerciser returns an error code 
#57H Invalid Configuration if there are no 
cartridges loaded into the unit, or if any drive is 
full. Requires one loaded cartridge.
Table B-13 Sequence Tests (For models 40fx, 80ex, 125ex, and 220mx ONLY)
No.  Test Name  Description