Optical Drive and Library SCSI-2 Command Reference
Autochanger Error Codes
Jukebox Micro-Move Error Codes
Appendix B B-47
 Autochanger Error Codes
16 Drive I/O Test Performs a combination of moves with a pass/fail 
result. It moves a cartridge from a randomly- 
chosen full slot to a drive, with a random flip. It 
then moves the cartridge back to its original slot 
with its original orientation. It does this once for 
each optical drive. Returns an error code #57H 
Invalid Configuration if there are no cartridges 
loaded into the unit. Requires one loaded 
cartridge; drives must be empty.
17
Mailslot I/O Performs a combination of moves with a pass/fail 
result. It moves a cartridge from the lowest- 
numbered full slot to the mailslot with a random 
flip. It then moves the cartridge back to its 
original slot with its original orientation. 
Returns an error code #57H Invalid 
Configuration if there are no cartridges loaded 
into the unit. Requires one loaded cartridge; 
mailslot must be empty.
18
Speed Factor Setting 
Utility
Allows the setting of the speed factor as the first 
parameter given. The speed factor determines 
how fast the system moves the mechanics. The 
number provides 1/Parameter speed (e.g. 
Parameter=3 runs the motors at 1/3 of full 
speed). This test can only be run from the SCSI 
Interface.
19
Zero Maximum Force 
Log
The maximum force log is initialized to all zeros.
20
Set Speed Factor to 
Full Speed
Allows the mechanics to be run at full speed.
21
Set Speed Factor to 
Half Speed
Allows the mechanics to be run at half speed.
22
Set Speed Factor to 
Quarter Speed
Allows the mechanics to be run at quarter speed.
Table B-13 Sequence Tests (For models 40fx, 80ex, 125ex, and 220mx ONLY)
No.  Test Name  Description