 Autochanger Error Codes
34 SCSI Interface 
Controller Chip Test
Checks out operations of the SCSI interface 
controller chip. This test will not be run if 
initiated via SCSI, it reports PASS.
36
Motor Control Chip 
Test
Exercises the registers of the motor control IC. 
In order to perform correctly, this test shuts 
down the servo system.
37
Drive Connect Test Checks for expected drive configuration. This is 
done by polling the drive connect signal on each 
of the possible drives. This line is grounded at 
the drive end if a drive is connected. If the drives 
physically connected do not match the expected 
configuration then an error is reported.
38
Control Panel Light 
Show &Button Test
Lights each portion of the display individually 
and then together. Requires pushing each front 
panel button to finish the test.
40
Power Supply Test Looks at both the 12-Volt and the 24-Volt power 
supplies to verify that they are within limits. 
The limits for the 12V supply are 11V and 13V 
and the 24V supply limits are 23.5V and 25.5V.
41
SCSI Connector 
Loopback Test
(Interactive)
Performs a loopback through SCSI connectors, 
checking proper operation of the SCSI drivers, 
receivers, and cables. Requires an external 
loopback hood with terminator power. Will not 
run if it was initiated via SCSI; if so, it reports 
error FCH Test Did Not Run.
42
Optical Sensor Test 
(Interactive if done 
through the control 
panel)
Checks the status of the optical sensors. Also 
checks the status of the mailslot sensor (see Test 
43). "0"s are placed on the control panel display 
on the left and right of the display. The mark is 
an open zero if the sensor is not blocked, and a 
zero filled in with lit segments if a sensor is 
blocked. No FRU is returned.
Table B-13 Sequence Tests (For models 40fx, 80ex, 125ex, and 220mx ONLY)
No.  Test Name  Description