Optical Drive and Library SCSI-2 Command Reference
Micro/Macro-Moves
HP Surestore Optical Micro-Move IDs
Appendix DD-10
AB Move picker plunge assembly forward a small amount to 
complete the rearm of the picker mechanism. One of 
three moves used to make the top picker the active picker 
during a picker recalibration.
AC Move picker plunge assembly forward to normal position 
after a active picker has been change by micro-moves AA 
and AB. One of three moves used to make the top picker 
the active picker during a picker recalibration.
AD Move the picker plunge assembly a small amount away 
from the flip mechanism so that the mechanism is 
rearmed for a flip. Used in a flip sequence.
AE Move the picker plunge assembly out a small amount 
from the full retracted position to relieve the pressure on 
the mechanism after a flip.
AF First of two moves to move the thumb to the magazine 
during an ISTAT when no cartridge is in the picker. Next 
move is micro-move B0.
B0 Second of two moves to move the thumb to the magazine 
during an ISTAT when no cartridge is in the picker. Slow 
move to check for an overforce (cartridge in the magazine 
slot).
B1 Retract picker plunge assembly back into the picker to a 
point where the thumbs can unsplay. Used during an 
ISTAT, with no cartridge in the picker, when the thumbs 
are splayed and are they must be unsplayed.
B2 Retract picker plunge assembly into the picker to a point 
just short of where the thumbs would be released and 
unsplay. Used during an ISTAT, with no cartridge in the 
picker, when the thumbs are splayed and must be kept 
splayed.
Table D-1 HP Surestore Optical Micro-Move ID Table
(For all models, EXCEPT 40fx, 80ex, 125ex and 220mx)
Move ID 
(hex.)
Description