HP SureStore AutoBackup Administrator's Guide - Not Orderable

Integrity Check Failed Web:
YES Critical
LCD: YES
Status Light:
Flashing
YELLOW
An internal error occurred during
the Integrity Check job. Some
parts of program code may be
missed or corrupted. To repair a
corruption of the system software
you can manually reset the system
software using the Advanced
Administration options
User-initiated via detailed
message page
Integrity Check Failed Web:
YES Critical
LCD: YES
Status Light:
Flashing
YELLOW
The AutoBackup backup data was
found to be corrupted during the
Integrity Check job. To repair a
data corruption of the backup data,
you can either manually reset the
system software with the option
set to delete the data (using the
Advanced Administration
options), or you can perform an
appliance recovery from tape if
you have a tape backup of your
HP SureStore AutoBackup
system.
User-initiated via detailed
message page
Integrity Check Failed Web:
YES Critical
LCD: YES
Status Light:
Flashing
YELLOW
The integrity check was canceled
because the tape backup started
before the integrity check had
completed. You must use the
"Manage Tape Backup and
Recovery" administration task to
change the tape backup schedule
to a different time of day so that
the integrity check completes
before the tape backup job is
scheduled to start or the tape
backup completes before the
integrity check is scheduled to
start. You can use the Advanced
Administration console to check
the scheduled start time of the
integrity check job.
User-initiated via detailed
message page
Integrity Check Failed Web:
YES Critical
LCD: YES
Status Light:
Flashing
YELLOW
The integrity check failed to run
because the tape backup was still
running when the integrity check
was scheduled to start. You must
use the "Manage Tape Backup and
Recovery" administration task to
change the tape backup schedule
to a different time of day so that
the integrity check completes
before the tape backup job is
scheduled to start or the tape
backup completes before the
integrity check is scheduled to
start. You can use the Advanced
Administration console to check
the scheduled start time of the
integrity check job.
User-initiated via detailed
message page
Troubleshooting, Alert Messages
file:///D|/ADMIN_~1/eng/trouble/alerts.htm (14 of 23) [5/3/2000 3:34:44 PM]