HP SureStore AutoBackup Administrator's Guide - Not Orderable

+3.3 volts
Crossed lower critical
Web:
YES Critical
LCD: YES
Also display voltage
icon
Status Light: Flashing
YELLOW
+3.3 volts Crossed lower critical
Please click on the URL below to
get details
Help configuring thresholds for
+3.3 volts
If +3.3V voltage falls
below 3.1V, then system
performs an automatic
shutdown!
+3.3 volts
Back to Normal
Web:
YES Warning
LCD: YES
Status Light: GREEN
+3.3 volts Back to Normal
Please click on the URL below to
get details
Help configuring thresholds for
+3.3 volts
Automatically cleared after
5 seconds
CPU I/O Voltage
Crossed upper
noncritical
Web:
YES Warning
LCD: YES
Also display voltage
icon
Status Light: Flashing
YELLOW
CPU I/O Voltage Crossed upper
noncritical
Please click on the URL below to
get details
Help configuring thresholds for
CPU I/O Voltage
User-initiated via detailed
message page, or
Automatically cleared
when power supply
problem is resolved
CPU I/O Voltage
Crossed upper critical
Web:
YES Critical
LCD: YES
Also display voltage
icon
Status Light: Flashing
YELLOW
CPU I/O Voltage Crossed upper
critical
Please click on the URL below to
get details
Help configuring thresholds for
CPU I/O Voltage
If CPU I/O Voltage
rises above 1.59V, then
system performs an
automatic shutdown!
CPU I/O Voltage
Crossed lower
noncritical
Web:
YES Warning
LCD: YES
Also display voltage
icon
Status Light: Flashing
YELLOW
CPU I/O Voltage Crossed lower
noncritical
Please click on the URL below to
get details
Help configuring thresholds for
CPU I/O Voltage
User-initiated via detailed
message page, or
Automatically cleared
when power supply
problem is resolved
Troubleshooting, Alert Messages