HP Surestore Bridge FC 2/1 LV and FC 4/1 HV Installation and Operations Guide

Chapter 6 Main Menu 139
Chapter 6
Select an AL_PA value from the table and enter it into the field Enter loop
address of AL_PA at the bottom of the screen.
For more information, see Appendix C.
Main Menu > Configuration > FC to SCSI Mapping
This menu allows for setting the Fibre Channel Address method, Hard Address
value, discovery mode, WWN overrides and FC Port mode.
Figure 44 FC to SCSI Mapping Page
Mode Selection determines the mode of Fibre Channel to SCSI Mapping.
The following options are available:
SCC
Indexed
Auto-assigned, LUN priority
Auto-assigned, target ID priority
Auto-assigned, bus number priority
SCC mode is used to address SCSI devices attached to the bridge using
the SCSI-3 Controller Commands method of logical unit addressing. In this
mode, the bridge will respond to FCP commands as in a SCC controller
device. The FC HBA must support this addressing method.