HP Surestore Bridge FC 2/1 LV and FC 4/1 HV Installation and Operations Guide

Chapter 6 Main Menu 155
Chapter 6
Main Menu > Utilities > Trace Settings
This menu allows for setting the trace settings for the bridge.
Figure 57 Trace Settings Page
This menu toggles the current trace settings to either ON or OFF. Event logging
captures up to the last 215 events and then starts overwriting the log when full.
Level 0 is for Errors and Exceptions
Level 1 is for major Fibre Channel Events
Level 2 is for major Bridge Events
Level 3 is for major SCSI Events
Level 4 is for minor Fibre Channel Events
Level 5 is for minor Bridge Events
Level 6 is for minor SCSI Events
Level 7 is reserved for engineering code builds.
Select the
[Submit] button to update current operating trace levels. This
option forces the currently displayed trace settings to become effective
immediately, without requiring a reboot or power cycle.