HP Surestore Bridge FC 2/1 LV and FC 4/1 HV Installation and Operations Guide

Chapter 7 HP-UX Configuration 175
Chapter 7
d. Make a list of all the monitors and monitoring requests that have
“SCSI_tape” listed. (You modify these in the next step.)
e. Delete all monitoring requested for “SCSI_tape”. Use the modify
command:
—Type
[M]. The tool displays a list of all monitoring requests and
prompts for a number of the request to change.
Type the number of the request to modify. The tool displays a list of all
the monitors for that request and prompts for the monitor(s) to modify.
Enter the numbers of the monitors except the one listing SCSI_tape
(usually number 12).
Table 16
Monitors typically clumped with “SCSI_tape”
AutoRAID ses_enclosure
Default SCSI_tape
FC_adaptor FC60
TL_adaptor FW_SCSI
core_hw High_Availability
FC_hub lpmc
FC_SCSI_mux scsi123_em
FC_switch system_status
Table 17
Monitoring Requests
Send events generated by monitors <monitor list above>
with severity >= INFORMATION to TEXTLOG
/var/opt/resmon/log/event.log
Send events generated by monitors <monitor list above>
with severity >= MAJOR WARNING to SYSLOG
Send events generated by monitors <monitor list above>
with severity >= MAJOR WARNING to EMAIL root