HP Surestore Bridge FC 2/1 LV and FC 4/1 HV Installation and Operations Guide

188 Basic Verification Chapter 8
Device Recognition in HP-UX
Execute an ioscan command
The ioscan should list each tape drive and the robotics controller.
See Figure 79 on page 188.
Figure 79 ioscan Sample
#ioscan –fn –H 0/4
Class I H/W Path Driver S/W State H/W Type Description
==================================================================================
ba 4 0/4 lba CLAIMED BUS_NEXUS Local PCI Bus Adapter (782)
fc 0 0/4/0/0 td CLAIMED INTERFACE HP Tachyon TL/TS Fibre Channel
Mass Storage Adapter
/dev/td0
fcp 2 0/4/0/0.2 fcp CLAIMED INTERFACE FCP Domain
ext_bus 36 0/4/0/0.2.16.255.12 fcpdev CLAIMED INTERFACE FCP Device Interface
target 6 0/4/0/0.2.16.255.12.3 tgt CLAIMED DEVICE
autoch 13 0/4/0/0.2.16.255.12.3.0 schgr CLAIMED DEVICE HP A5617A
/dev/rac/c36t3d0
tape 81 0/4/0/0.2.16.255.12.3.1 stape CLAIMED DEVICE HP Ultrium 1-SCSI
/dev/rmt/81m
/dev/rmt/81mb
/dev/rmt/81mn
/dev/rmt/81mnb
/dev/rmt/c36t3d1BEST
/dev/rmt/c36t3d1BESTb
/dev/rmt/c36t3d1BESTn
/dev/rmt/c36t3d1BESTnb
ctl 219 0/4/0/0.2.16.255.12.3.2 sctl CLAIMED DEVICE HP A4689A
/dev/rscsi/c36t3d2
ext_bus 29 0/4/0/0.2.20.255.12 fcpdev CLAIMED INTERFACE FCP Device Interface
target 7 0/4/0/0.2.20.255.12.3 tgt CLAIMED DEVICE
tape 73 0/4/0/0.2.20.255.12.3.0 stape CLAIMED DEVICE HP Ultrium 1-SCSI
/dev/rmt/73m
/dev/rmt/73mb
/dev/rmt/73mn
/dev/rmt/73mnb
/dev/rmt/c29t3d0BEST
/dev/rmt/c29t3d0BESTb
/dev/rmt/c29t3d0BESTn
/dev/rmt/c29t3d0BESTnb
tape 51 0/4/0/0.2.20.255.12.3.1 stape CLAIMED DEVICE HP Ultrium 1-SCSI
/dev/rmt/75m
/dev/rmt/75mb
/dev/rmt/75mn
/dev/rmt/75mnb
/dev/rmt/c29t3d1BEST
/dev/rmt/c29t3d1BESTb
/dev/rmt/c29t3d1BESTn
/dev/rmt/c29t3d1BESTnb
ctl 143 0/4/0/0.2.20.255.12.3.2 sctl CLAIMED DEVICE HP A4689A
/dev/rscsi/c29t3d2
ext_bus 33 0/4/0/0.2.23.255.0 fcpdev CLAIMED INTERFACE FCP Device Interface