208 In-Band Management Appendix B
In-Band Management
Following are descriptions of some of the Controller LUN commands used for
In-Band Management of the bridge.
Download Command
The Download (WRITE_BUFFER) command is used to transfer firmware to the
bridge over Fibre Channel. Multiple WRITE_BUFFER commands will be
required to accomplish the total transfer. All write commands except the final
write will have the 3-bit Mode field set to 0x06. The last write command in the
sequence will have the Mode field bits set to 0x07 to signify the end of transfer.
Each WRITE_BUFFER command will return an FCP response. Upgrading the
firmware is successful when the FCP response returns 0x00 (success). When
the transfer process is complete and the firmware image has been successfully
written to FLASH, the bridge will respond to the last transfer with 0x00, then
re-boot with the upgraded firmware. If any errors occur, the Controller will
return an FCP_RSP response RC value other than 0x00 and the bridge will
abort the upgrade. In this case, the bridge will not re-boot and the previous
version of firmware will remain intact. The host will issue a WRITE_BUFFER
command as described in Table 9 on page 209.