HP Surestore Bridge FC 2/1 LV and FC 4/1 HV Installation and Operations Guide

Appendix B In-Band Management 213
If the EVPD bit is set and the Page Code is 0x80 the unit serial number page is
returned. The format of this page is shown in Table 10 on page 211. The
serial number field is a sixteen-byte left justified ASCII string.
The bridge returns the LUN Inquiry Data as defined in Table 13 .
Table 12 Format of EVPD Page 0x80
Bit
Byte
7 6 5 4 3 2 1 0
0
Operation Code (0ch)
1
Page Code (80h)
3
Reserved
4
Page Length
5
...
20
Serial Number
Table 13 LUN Inquiry Data
Item Value
Peripheral Qualifier 0x00
Peripheral Device Type 0x0C - Indicates bridge/bridge function
RMB 0x00
Device Type Qualifier 0x00
ISO Version 0x00
AENC 0x00
TrmIOP 0x00
Response Data Format 0x02 - SCSI-2 Inquiry Data Format
Additional Length 0x20