HP Surestore Bridge FC 2/1 LV and FC 4/1 HV Installation and Operations Guide

Chapter 3 Interfaces and Connections 65
Chapter 3
Autobaud Feature
The autobaud feature automatically configures the baud rate on the bridge.
Once you set the baud rate in the terminal emulation program, wait until the
bridge completes the power-on self test (POST) and then the firmware
initialization process. This can take up to 90 seconds. Press the
[Enter] key
slowly 7 or 8 times and the bridge will automatically detect the baud rate. The
baud rate is then saved in the bridge’s configuration and will be retained
through future power cycles. After establishing a baud rate, it is recommended
to save the current configuration so the selected baud rate becomes the default
setting.
Note Pressing the [Enter] key before the POST has completed has no
effect on the autobaud feature. Wait until both the POST and the
firmware initialization processes have completed before pressing
the [Enter] key (this may take up to 90 seconds).
The baud rate in the terminal emulation program must be set at 9600, 19200,
38400, 57600, or 115200 for the autobaud feature to recognize it. The
bridge will not function properly at any other baud rate.