HP Surestore Bridge FC 2/1 LV and FC 4/1 HV Installation and Operations Guide

Chapter 3 Installing Cables 67
Chapter 3
Note A basic point-to-point (PPP) configuration is one HBA to one
bridge.
Note All SCSI targets in an MO jukebox must be connected to a single
bridge using a single SCSI connection. SCSI targets in a two-bus
MO jukebox may be connected using a double SCSI connection.
3. Connect one end of the optical cable into the GBIC on the bridge and the
other end into the Fibre Channel HBA in the host (the HBA may also
require a GBIC).
4. Connect the power cord from the bridge to a power strip in the library.
5. Confirm that all cable ends are connected securely and that the end of
each bus is properly terminated. The bridge, in its default configuration,
provides internal termination at the end of each SCSI bus.
6. See Powering on the System on page 76.
Figure 26 Fibre Bridge Connection, Basic Configuration for the FC 2/1 LV