HP Surestore Bridge FC 2/1 LV and FC 4/1 HV Installation and Operations Guide

88 Perform Configuration Chapter 4
Select 4) to toggle the FC Port Mode.
Auto Sense - Soft AL_PA: In this mode, the bridge FC port tries to
come up as a loop and if not successful then tries to come up as a
fabric. If the port comes up as a loop, it then determines whether it’s
on a private or public loop.
N_Port: In this mode, the bridge’s FC port skips trying to come up as
a loop and instead tries coming up as a fabric only. If the bridge is on
a loop and N_Port mode is selected, an error in communication may
occur.
Auto Sense - Hard AL_PA (default setting): In this mode, a unique
one-byte valid value (derived from an Arbitrated Loop Topology as
defined in ANSI specifications FC_AL ver 4.5) is used for the Fibre
Channel configuration. When configuring the Fibre Channel AL_PA,
the bridge presents a list of loop addresses along with the
corresponding AL_PA. From here, the user can select the loop address
desired.
Select 5) to change the ALPA Value: When Auto Sense - Hard AL_PA is
selected, you can set the Hard AL_PA value by entering a node number
from the AL_PA lookup table that appears when this option is selected.
This option only appears when the FC Port Mode is set to Auto Sense -
Hard AL_PA.