HP Surestore Bridge FC 2/1 LV and FC 4/1 HV Installation and Operations Guide

90 Perform Configuration Chapter 4
Select 1) to change the initiator SCSI ID. This is the ID for the SCSI
device that requests operations from other SCSI devices known as targets.
This should be a unique ID on the bus, the default is 7.
Select 2) to add a target SCSI ID. This section is used only when the
bridge is configured as a SCSI target for use with SCSI initiators. This is
NOT relevant to the use of the bridge in a tape library or MO jukebox.
This adds an ID for a SCSI device that responds to operation requests from
the SCSI initiator. This must be setup before users can access SCSI to Fibre
Channel mapping (from the SCSI to Fibre Channel Mapping
Configuration menu).
Select 3) to remove a target SCSI ID. This section is used only when
the bridge is configured as a SCSI target for use with SCSI initiators.
This is NOT relevant to the use of the bridge in a tape library or MO
jukebox.
This option eliminates target IDs previously added.
SCSI Configuration Menu
Version X.X XXXX
Bus 1, Current SCSI Configuration:
Initiator SCSI ID: 7
Target SCSI ID(s):
Reset SCSI Bus on Boot: Yes
SCSI Initial Discovery Delay: 2000 ms
Initiator Mode Buffered Tape Writes: Enabled
Target Mode Buffered Tape Writes: Disabled
SCSI Termination: Internal
1) Change Initiator SCSI ID
2) Add Target SCSI ID
3) Remove Target SCSI ID
4) Toggle SCSI Reset Operation
5) Change Discovery Delay Time
6) Toggle Initiator Mode Buffered Tape Writes
7) Toggle Target Mode Buffered Tape Writes
8) Toggle SCSI Termination Mode (FC 2/1 only)
X) Return to previous menu