HP Surestore Bridge FC 2/1 LV and FC 4/1 HV Installation and Operations Guide

100 Perform Configuration Chapter 4
Enter a level number from the Trace Settings that are shown. This toggles the
current setting to either ON or OFF. Event logging captures up to the last 215
events and then starts overwriting the log when full.
Level 0 is for Errors and Exceptions
Level 1 is for major Fibre Channel Events
Level 2 is for major Bridge Events
Level 3 is for major SCSI Events
Level 4 is for minor Fibre Channel Events
Level 5 is for minor Bridge Events
Level 6 is for minor SCSI Events
Levels 7-D are reserved for engineering code builds
Select U) to update current operating trace levels. This option forces the
currently displayed trace settings to become effective immediately, without
requiring a reboot or power cycle.
Note So that event logging is accurate, be sure to correctly set the
clock and date in the Real Time Clock Configuration menu.