SAN Solution Installation Guide

Installation
Tape Libraries
Chapter 2 2-25
4. When the screen displays your desired setting, press the
[SELECT]
button from the right-most field to save the changes. To abort, press
the
[MENU] button from the left-most field.
5. If you have already changed the library’s SCSI ID and are planning to
exit the
Main Configuration menu at this time, you must press the
[RESET] button. If you wish to set other configuration values, continue
with the next section, “Drive Entries.”
Drive Entries
Information in this section refers to the 9840, DLT 7000 and DLT 8000
drives.
NOTE For you to be able to configure a 9840 drive’s SCSI ID and bus status from
the library’s operator panel, the drive must have firmware version 1.24 or
later.
To check the drive’s firmware version, select
[DRIVE INFO] from the main
menu. Configuring a tape drive might involve more than setting the
drive’s SCSI ID and bus status.
For more information about 9840 drive configuration options and
instructions, refer to the 9840 Tape Drive Installation Guide, Part
Number A5598-96001..
Two entries at the library operator panel complete the configuration
choices for each drive installed in the library.
SCSI ID
Bus status (on or off bus)
NOTE “On Bus” means that the drive is on the same SCSI bus as the library. “Off
Bus” means that the drive is not on the same SCSI bus as the library.
You can set the drive SCSI IDs and bus status choices from the
Drive
Configuration
menu. You can enter both values for each drive at the same
time:
1. At the
Main Configuration menu, press an arrow key until the cursor
underscores
DRIVE CONFIG.