fw 05.01.00 and sw 07.01.00 - Universal Port Module Kit - Installation Instructions

Installation Instructions
23Universal Port Module Kit Installation Instructions
Caution: The torque tool supplied with the director is designed to tighten
logic cards and is set to release at a torque value of six inch-pounds. Do not
use an Allen wrench or torque tool designed for use with another HP or
Compaq product. Use of the wrong tool may overtighten and damage logic
cards.
a. Insert the torque tool into the cam Allen screw (uncolored). Turn the
torque tool clockwise until you feel it release and hear a clicking sound.
As the screw turns clockwise, the card cams into the backplane connector.
b. Insert the torque tool into the locking Allen screw (yellow). Turn the
torque tool clockwise until you feel it release and hear a clicking sound.
As the screw turns clockwise, the card locks into place.
c. Verify the card stiffener is flush with the front of the card cage and even
with other director logic cards.
5. Perform an external loopback test for all ports on the replacement UPM card.
For instructions, refer to External Loopback Test and return here. If the test
fails, see the Maintenance Analysis Procedures (MAP) in the Diagnostics
chapter of the HP StorageWorks Director 2/64 Service Manual or
HP StorageWorks Director 2/140 Service Manual to isolate the problem.
6. Disconnect the ESD wrist strap from the director chassis and your wrist.
7. Inspect the UPM card to ensure all amber LEDs are extinguished. If any
amber LEDs are illuminated, go to MAP 0000: Start MAP of the
HP StorageWorks Director 2/64 Service Manual or HP StorageWorks
Director 2/140 Service Manual to isolate the problem.
8. At the HA-Fabric Manager server, open the HA-Fabric Manager
application. The Product View displays.
9. Double-click the icon representing the director for which the loopback test
will be performed. The Hardware View for the selected director displays.
10. Choose Event Log from the Logs menu. The Event Log displays. Ensure the
following event codes display in the log:
500 - UPM card hot-insertion initiated.
501 - UPM card hot-insertion completed.
If an event code 501 does not display in the log, go to MAP 0000: Start MAP
of the HP StorageWorks Director 2/64 Service Manual or HP StorageWorks
Director 2/140 Service Manual to isolate the problem.