fw 05.01.00 and sw 07.01.00 - Universal Port Module Kit - Installation Instructions

Installation Instructions
24 Universal Port Module Kit Installation Instructions
11. At the Hardware View, double-click the graphic representing the
replacement card to open the Port Card View. At the Port Card View:
a. Ensure no alert symbols display that indicate a failure (yellow triangle or
red diamond).
b. Verify UPM card information (FRU name, position, and state) is correct.
If a problem is indicated, go to MAP 0000: Start MAP of the
HP StorageWorks Director 2/64 Service Manual or HP StorageWorks
Director 2/140 Service Manual to isolate the problem.
12. Close and lock the equipment cabinet door.
13. Initiate communication to the UPM card and set the card online as needed.
For instructions, refer to Unblocking a UPM Card.
Miscellaneous Procedures
The following are miscellaneous procedures that you can perform on your UPM
card.
External Loopback Test
To perform an external loopback test for a single port or a UPM card (four ports):
1. If the UPM card is currently being used in a fabric, then notify storage users
on the fabric that a disruptive external loopback test will be performed on a
port or UPM card, and the fiber optic cable or cables will be disconnected.
Ensure the system administrator queues Fibre Channel frame traffic through
the port or UPM card and sets attached devices offline.
Note: At the start of the loopback test, the port or UPM card can be online, offline,
blocked, or unblocked.
2. At the HA-Fabric Manager server, open the HA-Fabric Manager
application. The Product View displays.
3. Double-click the icon representing the director for which the loopback test
will be performed. The Hardware View for the selected director displays.
4. At the Hardware View, verify the location of the port or UPM card to be
tested. When the mouse cursor is passed over a graphical UPM card on the
front view of the director, the card highlights with a blue border and a pop-up
displays with the following information: