HP Surestore Director FC-64 Command Line Interface User's Guide
config 37
CLI Commands
Command Ex ample
Root >
config snmp show
Output
The switch configuration data is displayed as a table that includes the following properties
Output Example
The output from the config.snmp.show command displays as follows.
Authorization Traps: Enabled
Index Community Name WriteAuth Trap Recipient UDP Port
----- -------------------------------- --------- --------------- --------
1 CommunityName1 Enabled 123.123.123.123 162
2 CommunityName2 Enabled 10.25.25.10 144
3 CommunityName3 Disabled 132.44.85.224 162
4 public Enabled 162
5
6
commIndex The community index number.
commName The name of the community.
writeAuthorization The write authorization state.
trapRecipient The address of the trap recipient.
udpPortNum The UDP port number to which the director will send traps for each recipient.