HP Surestore Director FC-64 Command Line Interface User's Guide
74 perf
Output Example
The output from the perf.erro rs c ommand displays as fo llows.
Port Prim Seq Err Disc Frms Inv Tx Wrds CRC Errs Delim Errs Addr Id Errs
---- ------------ --------- ----------- -------- ---------- ------------
0 0 0 0 0 0 0
1 0 0 1284899 1 0 0
2 0 0 0 0 0 0
3 0 0 0 0 0 0
4 0 0 8 0 0 0
5 0 0 0 0 0 0
6 0 0 305233444 0 0 0
7 0 0 0 0 0 0
8 0 0 456 0 0 0
9 0 0 0 0 0 0
10 0 0 0 0 0 0
11 0 0 0 0 0 0
12 0 0 0 0 0 0
13 0 0 0 0 0 0
14 0 0 123527 21 0 0
15 0 0 0 0 0 0
CRC Errs The number of frame CRC errors detected by the port.
Dlim Errs The number of invalid frame delimiters (SOF or EOF) received by the port.
Addr Id Errs The number of frames received with unknown addressing.