HP Surestore Director FC-64 Product Manager User's Guide

Hardware View 71
Monitoring and
Managing the Director
connected to another director or a switch. This field displays NA if a segmented
E_Port or invalid attachment operating state has not occurred.
Refer to the section on joining zoned fabrics in the hp surestore director fc-64
Planning Guide (A6534-90903).
Reason messages for segmentation can include:
Incompatible operating parameters. Operating parameters, such as resource
allocation time-out values (R_A_TOV) or error-detect time-out values (E_D_TOV),
are inconsistent. Refer to Configure Operating Parameters on page 110 for more
information.
Duplicate domain IDs. Identical preferred domain IDs are configured for two or
more directors or switches. Refer to Configure Operating Parameters on page 110
for more information.
Incompatible zoning configurations. Refer to the hp surestore director fc-64
Planning Guide (HP A6534-90903) and the hp surestore director fc-64 Installation
and Service Manual (HP A6534-90902) for more information on zoning.
Build fabric protocol error.
No principal switch. A principle switch is not defined for the fabric.
No response from the attached switch.
Reason messages for an invalid attachment can include:
01 Unknown. The reason is not known.
02 ISL connection not allowed on this port. ISL is connected to a port configured as
an F_Port.
03 ELP rejected by the attached switch. This director or switch transmitted an
exchange link protocol (ELP) frame that was rejected by the switch at the other end
of the ISL.
04 Incompatible switch at other end of the ISL. The switch is configured for Open
Fabric mode, and the switch at the other end of the ISL is a McDATA switch
configured for McDATA Fabric mode.