User's Guide
232$SSHQGL[
&DSDELOLW\*URXS7DEOH
7KH)FFISRUWFDSWDEOHGLVSOD\VWKHFDSDELOLWLHVRIWKH)B3RUWZLWKLQWKHIDEULFHOHPHQW
E_D_TOV Error detect time out value configured for the F_Port. The
Error_Detect_Timeout Value is used as the timeout value for detecting an error
condition.
ClassSvcSupt Value indicating the set of classes of service supported by the F_Port.
IntermixSupt Flag indicating if the F_Port supports an intermixed dedicated connection. The
flag is always at no(2).
StackedConMo
de
Value indicating the mode of stacked connect supported by the F_Port. The
value is always at none(1).
C2SeqDelivery Flag indicating if class 2 sequential delivery is supported by the F_Port.
C3SeqDelivery Flag indicating if class 3 sequential delivery is supported by the F_Port.
HoldTime Maximum time (in microseconds) the F_Port holds a frame before discarding
the undeliverable frame. The value 0 means that the F_Port does not support
this parameter.
BaudRate FC-0 baud rate of the F_Port.
Medium FC-0 medium of the F_Port.
TxType FC-0 transmitter type of the F_Port.
Distance FC-0 distance range of the F_Port transmitter.
7DEOH &DSDELOLW\*URXS7DEOH
Variable Provides
CapModuleIndex Module index.
FxPortIndex Port index.
FC-PHVersionHigh Highest or most recent version of FC-PH that the FxPort is capable of
supporting.
FC-PHVersLow Lowest or earliest version of FC-PH that the F_Port is capable of supporting.
BBCreditMax Maximum number of receive buffers available for holding a class 1 connect-
request, or class 2 or class 3 frames from the attached N_Port.
7DEOH &RQILJXUDWLRQ7DEOHFRQWªG
Variable Provides: