User's Guide

8VLQJWKH3URGXFW0DQDJHU 77
Product Manager
Overview
0DLQ3DQHO
7KHPDLQSDQHOGLVSOD\VWKH+DUGZDUH9LHZ3RUW/LVW9LHZ)58/LVW9LHZ1RGH/LVW9LHZ
DQG3HUIRUPDQFH9LHZ3ODFHWKHFXUVRURYHUWKH9LHZLFRQDQGVHOHFWRQHRIWKHRSWLRQV
IURPWKHSRSXSPHQX)RUGHWDLOHGLQIRUPDWLRQRQXVLQJWKHVHYLHZVUHIHUWR&KDSWHU
7DEOH
2SHUDWLQJ6WDWXV$OHUW3DQHODQG'LUHFWRU6WDWXV
Symbol
Alert
Panel
Operator
Panel Text
Director Status Table
Text Meaning
Green
Circle
Online or
Offline
Fully Operational All components and installed ports
are operational; no failures.
Yellow
Triangle
Degraded Redundant Failure A redundant component has failed,
such as a power supply, and the
backup component has taken over
operation.
Minor Failure A failure occurred which has
decreased the director operational
ability. Normal switching operations
are not affected.
One or more FPM cards failed, but
at least one FPM card is still
operational.
A fan has failed or is not rotating
sufficiently.
One of two CTP cards failed.
One of two SBAR cards failed.
Red
Diamond
with Yellow
Backgroun
d
Failed NOT OPERATIONAL A critical failure prevents the
director from performing
fundamental switching operations.
- All fans fail.
- Both SBAR cards fail.
- All installed FPM cards fail.