Disk Array FC60 User's Guide (A5635A)

Table Of Contents
'LVN$UUD\+LJK$YDLODELOLW\)HDWXUHV 43
Product Description
5$,'/HYHO&RPSDULVRQV
7RKHOS\RXGHFLGHZKLFK5$,'OHYHOWRVHOHFWIRUDYROXPHJURXSWKHIROORZLQJWDEOHV
FRPSDUHWKHFKDUDFWHULVWLFVIRUWKHVXSSRUWHG5$,'OHYHOV:KHUHDSSURSULDWHWKHUHODWLYH
VWUHQJWKVDQGZHDNQHVVRIHDFK5$,'OHYHODUHQRWHG

7DEOH
5$,'/HYHO&RPSDULVRQ'DWD5HGXQGDQF\&KDUDFWHULVWLFV
RAID Level Disk Striping Mirroring Parity
Handle multiple disk
failures?
RAID 0 Yes No No No. RAID 0 offers no data
redundancy or protection
against disk failure.
RAID 1 No Yes No No
RAID 0/1 Yes Yes No Yes, providing both disks in
a mirrored pair do not fail.
RAID 3 Yes No Yes No
RAID 5 Yes No Yes No
7DEOH 5$,'/HYHO&RPSDULVRQ6WRUDJH(IILFLHQF\&KDUDFWHULVWLFV
RAID Level Storage Efficiency
RAID 0 100%. All disk space is use for data storage.
RAID 1 and 0/1 50%. All data is duplicated, requiring twice the disk storage for a
given amount of data capacity.
RAID 3 and 5 One disk’s worth of capacity from each volume group is required to
store parity data. As the number of disks in the volume group
increases, so does the storage efficiency.
3-disk volume group: 66%
4-disk volume group: 75%
5-disk volume group: 80%
6-disk volume group: 83%