HP SureStore E Disk System HVD10 User and Service Guide - A5616-90901

9LHZ'LVN6WDWXV 103
Troubleshooting
)LJXUH 6DPSOH670([SHUW7RRO'LVN(UURU/RJ03(L;
Write Error Statistics
Errors Corrected Without Delay: N/A
Errors Corrected With Delay: 0
Total Retries: 0
Total Errors Corrected: 0
Correction Algorithm Executions: 0
Total Bytes Processed: 6.3253e+10
Total Uncorrected Errors: 0
Read Error Statistics
Errors Corrected Without Delay: 23781
Errors Corrected With Delay: 0
Total Retries: 0
Total Errors Corrected: 23781
Correction Algorithm Executions: 23781
Total Bytes Processed: 9.6191e+10
Total Uncorrected Errors: 0
Read Reverse Error Statistics
Errors Corrected Without Delay: N/A
Errors Corrected With Delay: N/A
Total Retries: N/A
Total Errors Corrected: N/A
Correction Algorithm Executions: N/A
Total Bytes Processed: N/A
Total Uncorrected Errors: N/A
Verify Error Statistics
Errors Corrected Without Delay: 0
Errors Corrected With Delay: 0
Total Retries: 0
Total Errors Corrected: 0
Correction Algorithm Executions: 0
Total Bytes Processed: 36864
Total Uncorrected Errors: 0
Non-Medium Error Counts: 0