Fabric OS Reference Manual

Telnet Commands 185
psShow
Display power supply status.
Synopsis
psShow
Availability All users
Description Use this command to display the switch power supply status.
The display format varies with switch model and number of power supplies
present.
The status of each supply is shown:
OK
Power supply present and functioning correctly.
absent
Power supply not present.
faulty
Power supply present but faulty (no power cable, power
switch turned off, fuse blown, or other internal error).
After the status line, a power supply identification line may be shown. If
present, this line contains manufacture date, part numbers, serial numbers,
and other identification information.
Operands None.
Example To view the status of the power supply for the current switch:
See Also
fanShow
tempShow
switch:admin> psShow
Power Supply 1 is OK
9835,DH000000208,60-0000734-01, A,00001, E108302A,01, 803350
Power Supply 2 is OK
9839,DH000000253,60-0000734-01, A,00001, E108302A,01, 803522