switchStatusPolicyShow
Displays the policy parameters that determine the overall switch status.
Synopsis
switchStatusPolicyShow
Availability All users
Description Use this command to view the current policy parameters set for the switch.
These policy parameters determine the number of failed or nonoperational
units allowed for each contributor before triggering a status change in the
switch.
The command will print the current parameters in a three-column table
format. The first column specifies the contributor; the second column
specifies the minimum number that contributes to the DOWN/FAILED
status; the third column specifies the minimum number that contributes to
the MARGINAL/WARNING status. The default values for the policy
parameters are shown in the following table.
The policy parameters determine the number of failed or nonoperational
units for each contributor that trigger a status change in the switch. For
example, if the FaultyPorts DOWN parameter is set to 3, and three ports
fail in the switch, then the status of the switch changes to DOWN.
Table 14. Contributor Value and Status
Contributor
Default Value for
DOWN
Default Value for
MARGINAL
FaultyPorts 2 1
MissingGBICs 0 0
PowerSupplies 2 1
Temperatures 2 1
Fans 2 1
PortStatus 0 0