Fabric OS Reference Manual

Error Messages 259
Diagnostic Error Messages
This section provides information on the probable cause of a diagnostic
error and what actions to take.
Table 18. Diagnostic Error Messages
Message Description Probable Cause Action
DIAG-BADINT
Err#1030, 2030
[centralMemoryTest,
cmiTest]
Port received an unexpected
interrupt
ASIC failure Replace
mainboard
assembly
DIAG-BUS_TIMEOUT
Err#0BoF, 4040F
[portRegTest,
sramRetentionTest]
ASIC register or ASIC SRAM
did not respond to an ASIC data
access
ASIC failure Replace
mainboard
assembly
DIAG-CAMINIT
Err#223B
[camTest]
Port failed to initialize due to one
of the following reasons:
switch not disabled
diagnostic queue absent
malloc failed
chip is not present
port is not in loopback mode
port is not active
Software
operational
setup error or
mainboard
failure
Retry, reboot, or
replace mainboard
assembly
DIAG-CAMSID
Err#223C
[camTest]
ASIC failed SID NO translation
test
ASIC failure Replace
mainboard
assembly