Fabric OS Reference Manual

Error Messages 261
DIAG-CMIINVCAP
Err#2034
[cmiTest]
Unintended ASIC erroneously
got CMI capture flag
ASIC or
mainboard
failure
Replace
mainboard
assembly
DIAG-CMINOCAP
Err#2033
[cmiTest]
CMI intended receiver ASIC
failed to get CMI capture flag
ASIC or
mainboard
failure
Replace
mainboard
assembly
DIAG-CMISA1
Err#2032
[cmiTest]
An attempt to send a CMI
message from ASIC to ASIC
failed
ASIC failure Replace
mainboard
assembly
DIAG-CMNOBUF
Err#1029
[centralMemoryTest]
Port could not get any buffer ASIC failure Replace
mainboard
assembly
DIAG-DATA
Err#266E, 306E
[portLoopbackTest,
crossPortTest]
Payload received by port did not
match payload transmitted
mainboard,
GBIC module,
or fibre cable
failure
Replace
mainboard
assembly, GBIC
module, or fibre
cable
Table 18. Diagnostic Error Messages (continued)
Message Description Probable Cause Action