Fabric OS Reference Manual

262 Fabric OS Reference Manual
DIAG-ERRSTAT
Err#2640-2647,
3040-3047, 3840-3847
[portLoopbackTest,
crossPortTest, spinSilk]
Port Error Statistics counter is
nonzero, meaning an error was
detected when receiving frames.
One of the following status errors
occurred:
Enc_in Encoding error,
inside frame
CRC_err Cyclic redundancy
check on frame failed
TruncFrm Truncated frame
FrmTooLong Frame too
long
BadEOF Bad end of file
Enc_out Encoding error,
outside frame
BadOrdSet Bad symbol on
fiber-optic cable
DiscC3 Discarded Class 3
frames
ASIC,
mainboard,
GBIC module,
or fibre cable
failure
Replace
mainboard
assembly, GBIC
module, or fibre
cable
DIAG-INIT
Err#264F, 304F, 384F
[portLoopbackTest,
crossPortTest, spinSilk]
Port failed to go active in the
loopback mode requested
ASIC, main-
board, GBIC
module, or fibre
cable failure
Replace
mainboard
assembly, GBIC
module, or fibre
cable
DIAG-INTNIL
Err#2031
[cmiTest]
ASIC failed to get a CMI error
(interrupt)
ASIC failure Replace
mainboard
assembly
Table 18. Diagnostic Error Messages (continued)
Message Description Probable Cause Action