Fabric OS Reference Manual

Error Messages 263
DIAG-INTNOTCLR
Err#102C
[centralMemoryTest]
The interrupt bit could not be
cleared
ASIC failure Replace
mainboard
assembly
DIAG-LCMEM
Err#1027
[centralMemoryTest,
cmemRetentionTest]
Data read from the Central
Memory location did not match
data previously written into the
same location
ASIC failure Replace
mainboard
assembly
DIAG-LCMEMTX
Err#1F27, 1028
[centralMemoryTest]
Central Memory transmit path
failure: ASIC 1 failed to read
ASIC 2 using the transmit path
mainboard
failure
Replace
mainboard
assembly
DIAG-LCMRS
Err#1F25, 1025
[centralMemoryTest,
cmemRetentionTest]
Central Memory Read Short: M
bytes requested but not received
ASIC failure Replace
mainboard
assembly
DIAG-LCMTO
Err#1F26, 1026
[centralMemoryTest,
cmemRetentionTest]
Central Memory Timeout: Data
transfer initiated did not complete
within the time-out period
ASIC failure Replace
mainboard
assembly
DIAG-MEMNULL
Err#0112
[ramTest]
Test failed to malloc mainboard
failure
Replace
mainboard
assembly
Table 18. Diagnostic Error Messages (continued)
Message Description Probable Cause Action