Fabric OS Reference Manual

264 Fabric OS Reference Manual
DIAG-MEMSZ
Err#0111
[ramTest]
Memory size to be tested is less
than or equal to zero
mainboard
failure
Replace
mainboard
assembly
DIAG-MEMORY
Err#0110
[ramTest]
Data read from RAM location did
not match previously written data
into same location
CPU RAM
failure
Replace
mainboard
assembly or
DRAM module
DIAG-NOSEGMENT
Err#3081,3881
[crossPortTest,
spinSilk]
Port failed to go into loopback
mode
Improper GGIC
or cable
connection
Reseat GBICs and
cables and
re-execute test
DIAG-PORTABSENT
Err#2670, 3070, 3870
[portLoopbackTest,
crossPortTest, spinSilk]
Port is not present ASIC or
mainboard
failure
Replace
mainboard
assembly
DIAG-PORTDIED
Err#265F, 305F, 385F
[portLoopbackTest,
crossPortTest, spinSilk]
Port was in loopback mode and
then went inactive
ASIC, GBIC
module, or fibre
cable failure
Replace
mainboard
assembly, GBIC
module, or fibre
cable
DIAG-PORTM2M
Err#3080, 3880
[crossPortTest,
spinSilk]
Port is found to be connected to
itself (self loopback). This Port M
to Port M connection is not
allowed by the test
Improper cable
connection
Reconnect port
(M) to another port
(N) and re-execute
test
Table 18. Diagnostic Error Messages (continued)
Message Description Probable Cause Action